اخوي ابو فيصل والأ خوه المهتمين السلام عليكم ورحمة الله وبركاته
عندي هذى الجهاز معة قرص واحد فقط 35 ممكن تساعوني في الحصول على قرص 45
ثانيآ حاولت ترجمه الكتلوج ولأكن لم استطع الحصول على ترجمه صحيحة
مرفق نسخة من احد الصفحات مع صورة للجهاز مع العلم انة بولندي الصنع
ولكم الشكر و التقدير
[COLOR=window****] [/color]
Instruction of editing detector MAX VLF:
1. Install plastic tube on ****l and protect it by screw. To movable joint of probe put element joining probe with module. Through holes in movable joint of probe put plastic screw and wind up on screw nut. Cable of probe turn around tube going out from probe. Seize cable to tube. Detector is energized by vol***e [COLOR=window****]2x 9 V (2x for 6 batteries R6).[/color]
[COLOR=window****] [/color]
Service of detector:
1. Installation and checking admission:
A few advices at the beginning: detector must be checking outside the house, because of electric interferences and far away from high vol***e lines. During the firsts tries with detector put SENSITIVITY on „0 ”- it will be easier.
Switch ON- OFF is using to turn on and turn off detector. Switch ALL- DISC: ALL- detecting all ****ls. DISC- discrimination ****ls. Switch DISC BIG – DISC SMAL- decide what size ******s will be discriminated. Switch SPEAKER- turn on or turn off loudspeaker. The socket of receivers is from side.
2. Preparation detektor to work:
Keep detector 3 meters from ****l ******s. Turn on the detector. Potentiometer of volume put on „5 ”. At the beginning potentiometer of sensitivity put on „ 0”. Switching on in up button to reset detector ( it’s near shank on hand ). After pressing it, hand of measure will place on “ 0”. Signal in loudspeaker will be silent.
3. ASPECT FUNCTION „All ****ls „:
To start searching it's necessary to aspect potentiometer “ALL ****LS ”- it’ very important. To do it we: turn on detector and switch “MOTION ” set on “OFF “. Next switch set on “ ALL “.Raise probe over the ground , on about 40 cm.Press button “RESET”, thenleave hold of button and lower probe on distance 10 cm from the ground. Watch hand of measure. Set on potentiometer ” ALL ****LS “ to have hand of measure on the centre of the scale, during raising and lowering the probe (hand of measure can move from first “ 1 “ on scale to second). After every regulation by potentiometer “ALL ****LS “ press button“RESET”.
4. DISCRIMINATION ******S:
If we know where is centre of the ******, we can make a discrimination (check does the ****** is colored or steel). To do it set switch on “DISC “(discrimination).
Move away probe from ****** and raise on height 15- 30 cm over the ground. Press button “reset”, then leave hold of it and, WITHOUT CHANGING DISTANCE PROBE FROM GROUND, move detector to have center of probe above the ******.
Observe hand of measure. If the hand of measure will move on left, at “green“ ground of measure scale and signal in loudspeaker will be more quiet , then ****l is steel. If the hand of measure will move on right, at “red“ ground of measure scale and signal in loudspeaker will be stronger , then ****l is colored. In case of small ******s, switch of discrimination put on “D.SMALL”.Led green and red signalized “+” and “-“ of power supply.
5 . ADVICES:
Protect probe and electronic modules from humidity, high temperatures and mechanical damages. Be careful to don’t tear out cable from probe.
تعليق